About Always-Accurate Gas Mixer Array (HC Ver)
From Steam WorkshopCan generate multiple correct gas mixes even when input temperatures are different! For example: mix oxygen + nitrogen for breathing air, oxygen + 2 volatiles for fuel, and nitrous oxide + volatiles…
Can generate multiple correct gas mixes even when input temperatures are different!
For example: mix oxygen + nitrogen for breathing air, oxygen + 2 volatiles for fuel, and nitrous oxide + volatiles for superfuel (with low max pressure!) all from one IC housing.
This is the High-Comment Version for single control groups and for more easily reading the code to learn IC10 or examine how it works. For the Low-Comment Version that has room to add multiple mixer control groups, see here:
https://steamcommunity.com/sharedfiles/filedetails/?id=3590799744
To speed up the mixing of one combination of gases, you can use more than one gas mixer in a single group. Just make sure that they are all connected to the SAME pipe networks for inputs and outputs, and that each input gas is connected to the same port on each mixer (side or rear)! Then just give the mixers the same name, and the batch addressing will take care of it.
(Gas mixers are slow when the output pressure is high, but still, use caution to ensure that the output pipe network has sufficient volume. Inline tanks are your friend. Small and Big tanks are devices with separate volumes! It takes a tick for gases added to the pipe network to equalize into them. You may also consider using a lower output shutoff pressure, especially if the output pipe is not connected to any Small or Big tanks.)
To control the mixing of multiple different gas combinations from a single IC, you can use the Low-Comment version (see above). You can always run multiple instances of this version in different ICs, if you prefer.
Always-Accurate Gas Mixer Array (HC Ver) on Nxeon
From our catalogue- One-click install
- Not available. One-click install isn't available for this game's mods yet. Download it and upload it to your server in Files.
- Server load
- light
- Smallest plan we suggest
- Stationeers — 4 GB (4 GB RAM). This follows our own load rating above, not a benchmark.
Run Always-Accurate Gas Mixer Array (HC Ver) on a Stationeers server
Deploy a server above, then upload the file in Files.
What kind of mod it is
From the catalogLibraries & compatibility
Foundations and fixes other mods build on. Usually installed because something else needs it.
Compatibility
- Game
- Stationeers
- File size
- 455 KB
Verified at the source
- ✓Steam WorkshopOfficial listing, checked 2026-09-24Open ↗
- ✓AuthorTallinu, as published on Steam Workshop
- ✓LicenseNot published by the sourceFree
