About Atmospheric Realism Overhaul [Beta]
From Steam Workshopthis mod is currently outdated and not working! but it's not abandoned. update will come when time allows it Full list of changes: Version 0.14 Added realistic breathing. The fluctuation in your suit…
this mod is currently outdated and not working! but it's not abandoned. update will come when time allows it
[strike][h1]Full list of changes: [/h1] Version 0.14
- Added realistic breathing. The fluctuation in your suit pressure is your lungs expanding and contracting.
- Reduced Heat Exchanger mix rate without pressure difference.
- Added Heat Exchanger to atmos tablet. Hold Left-Shift to switch between the two internal atmospheres.
- Pipe radiators have reduced effect on stale gas. Keep the gas slightly moving for full effect. (10L pr tick movement gives full effect, no movement gives 30%)
- Change RatioOneAtmosphereClamped to sigmoid function. In practice this means convection and radiation scales with pressure all the way. 3kPa = 5%, 20kPa = 28%, 100kPa = 75%, 450kPa = 90%, 5MPa = 99%
- Corrected flow calculation.
- Slightly reduced overall gas mixing rate.
Version 0.13
- Fixed breathing bug.
- changed most flow and mix rates. Most notably large and medium radiators. These will mix very slowly with the connected pipe networks unless there is a pressure difference.
Version 0.12
- Fixed Ice Crusher bug.
- Implemented mod on remaining gas transfer methods.
- Added the extra atmosphere data to rooms.
Version 0.11
- Fixed gas mixing bug.
- Added max limit to AC (14kJ).
- Added information to atmos tablet:
- The molar value is "flow". Number of moles that went in and out during last tick. This is not change in total mole quantity. If 4 moles goes in & 6 moles goes out this will read as 4.
- The energy value is energy added or removed by this mod each tick. This is the adiabatic heating & cooling mostly, but it also shows AC energy transfers.
Version 0.10
- Volume pumps & Advanced Furnace Pump act as compressors. They are able to compress gas, thus move gas from a low-pressure pipe to a high pressure pipe.
- Volume Pumps & Advanced Furnace Pump power draw scales with compression work done to the gas.
- Active vents can only create limited pressure difference (2 atmospheres).
- Active vents move volumes of gas, not static mole amount. Creating vacuum will take significantly longer.
- Regulators/Mixer/AC/Filter/H2Combuster doesn't include a pump. They will still serve their functions but are unable to move gas "against the flow". They will process mass much faster on high pressure difference. (they move gas like one-way valves but while doing their function).
- Mixer output will equalize with lowest pressure input.
- Mixer will produce the exact mix the dial indicates, regardless of pressure and temperature differences.
- Filtration devices allow filtered and un-filtered gases to equalize independently.
- Filtration devices Filters degrade on filtered mole quantity, not time. (doesn't affect suit filters)
- Regulators/Mixer/Filter - Power draw reduced to 10W.
- Manual Valve & Digital Valve will not equalize instantly.
- Digital Valve Setting variable control valve opening (equalization speed).
- Gas Fuel Generator inputs 10 liters of input pipe content.
- Gas Fuel Generator pressure needle fixed and added damage on overpressure.
- Gas Fuel Generator Waste compression calculation: if the GFG needs to compress its internal combusted gas into the waste pipe, this compression energy will be subtracted from the power generated.
- Air Conditioner energy transfer will scale with throughput. Power draw scales with energy transfer & efficiency factors. Efficiency factor at 0% means power draw = infinite.
- Air Conditioner Temperature differential factor slightly kinder.
- Air Conditioner base power draw pr unit energy transfered increased roughly 4x.
- Turbine generator: power generated changed to use the same energy decompression math. Don't expect to be able to make infinite power loops. (But maybe if you find a rocket engine?)
Highlights
From source dataFootprint
A 1 MB download, rated a light load on a server.
Last update
Its author last shipped an update 4 yr ago.
Atmospheric Realism Overhaul [Beta] on Nxeon
From our catalogue- One-click install
- Not available. One-click install isn't available for this game's mods yet. Download it and upload it to your server in Files.
- Server load
- light
- Smallest plan we suggest
- Stationeers — 4 GB (4 GB RAM). This follows our own load rating above, not a benchmark.
- Latest build
- 2022-11-24, released 2022-11-24, 1 MB
Game versions by loader
| Loader | Game versions | Newest |
|---|---|---|
| Workshop |
From 1 recorded build of Atmospheric Realism Overhaul [Beta].
Run Atmospheric Realism Overhaul [Beta] on a Stationeers server
Deploy a server above, then upload the file in Files.
What kind of mod it is
From the catalogGameplay & overhauls
New mechanics, content and overhauls that change how the game plays.
Compatibility
- Game
- Stationeers
- File size
- 1 MB
Verified at the source
- ✓Steam WorkshopOfficial listing, checked 2026-10-10Open ↗
- ✓AuthorElmo, as published on Steam Workshop
- ✓LicenseNot published by the sourceFree
