About [F&S] Full Auto Airlock (Light Version)
From Steam WorkshopDescription Fully automated airlock, just build and forget. Retains the existing atmosphere in the pipe when the airlock closes, and release it when the same side is going to open again. Does not…
Description
Fully automated airlock, just build and forget. Retains the existing atmosphere in the pipe when the airlock closes, and release it when the same side is going to open again. Does not check the pressure behind the doors, if you need it, read the Related section.
Requirements
[olist] [*]1 Gas Sensor. [*]1 IC Housing. [*]1 Integrated Circuit (IC10). [*]1 Area Power Controller or Transformer. [*]1 Battery Cell (Large). [*]2 Doors any type. [*]2 Active Vent. [*]2 Pipe Analyzer. [*]2 Kit (Insulated Pipe). [*]3 Kit (Switch) (Lever) (Optional) [/olist]
IC ports description
[table] [tr] [th]Port[/th] [th]Device[/th] [/tr] [tr] [td]D0[/td] [td]DoorInt (Internal Door)[/td] [/tr] [tr] [td]D1[/td] [td]DoorExt (External Door)[/td] [/tr] [tr] [td]D2[/td] [td]GasInt (Internal Pipe Analyzer) (Optional not required)[/td] [/tr] [tr] [td]D3[/td] [td]GasExt (External Pipe Analyzer) (Optional not required)[/td] [/tr] [tr] [td]D4[/td] [td]VentInt (Internal Active Vent) (Optional not required)[/td] [/tr] [tr] [td]D5[/td] [td]VentExt (External Active Vent) (Optional not required)[/td] [/tr] [/table]
Changeable values in IC code
none
Important
You must separate the electrical lines with a transformer or APC, otherwise IC10 may read incorrect values. Kill Switches are optional but strongly recommended option. It is recommended to place a APC with a battery, so as not to get stuck in the airlock when the power goes out.
Emergency Kill Switch
Mortality among stationeers in the airlock is approaching 99%, in order to prevent this outcome, it is highly recommended to place emergency switches. When the emergency kill switch is switched, all doors are instantly unlocked, active ventilation is turned off and can be controlled manually. If you have lost electricity, the doors are not locked, you can open them with a crowbar.
Note
You can choose not to place 1 pipe analyzer and 1 active ventilation (Mode Pressure to Vacuum). You can choose not to place external and internal pipe analyzers with active ventilation (Mode Vacuum to Vacuum). It doesn't matter which side the external or internal exit (When ic10 switched on, the external door is always closed and the internal door opens). For pipe explosion protection, pressure is limited to 55 MPa. Original idea taken from the user: @HydrO
Related
Another version of the airlock https://steamcommunity.com/sharedfiles/filedetails/?id=2961762121
Door remote controller https://steamcommunity.com/sharedfiles/filedetails/?id=2962465193
Game version support
0.2.3920.18842 06/04/2023
[F&S] Full Auto Airlock (Light Version) on Nxeon
From our catalogue- One-click install
- Not available. One-click install isn't available for this game's mods yet. Download it and upload it to your server in Files.
- Server load
- light
- Smallest plan we suggest
- Stationeers — 4 GB (4 GB RAM). This follows our own load rating above, not a benchmark.
Run [F&S] Full Auto Airlock (Light Version) on a Stationeers server
Deploy a server above, then upload the file in Files.
What kind of mod it is
From the catalogQuality of life & UI
Small conveniences, tweaks and interface improvements players notice straight away.
Compatibility
- Game
- Stationeers
- File size
- 107 KB
Verified at the source
- ✓Steam WorkshopOfficial listing, checked 2026-09-24Open ↗
- ✓Author123, as published on Steam Workshop
- ✓LicenseNot published by the sourceFree