About [F&S] Industrial Heat Pump
From Steam WorkshopBROKEN Description Controls the temperature within the specified limits. Can be used to maintain the temperature in rooms, hydroponics, cool or heat gases and liquids to the desired level. Can…
BROKEN
Description
Controls the temperature within the specified limits. Can be used to maintain the temperature in rooms, hydroponics, cool or heat gases and liquids to the desired level. Can transfer a large amount of heat energy, up to 1 MJ (1000 wall heaters/coolers)
Warning
The system only works if there is no atmosphere on the planet. If there is an atmosphere, then it is only possible to heat.
Requirements
[olist] [*]1 IC Housing. [*]1 Integrated Circuit (IC10). [*]1 Area Power Controller or transformer. [*]1 Daylight Sensor. [*]1 Gas Sensor [*]1 Pipe Analyzer [*]1 Active Vent [*]1 Ice Crusher [*]4 Kit (Consoles) (Optional) [*]4 Circuits boards of Gas Display (Optional) [*]1 Insulated Liquid Tank (Small) [*]2 Heat Exchanger [*]1 Large Extendable Radiator [*]13 Kit (Wall) type - window(The type depends on the atmosphere of the planet(if have), check pressure/autoignition) [/olist]
IC ports description
Not used
Changeable values in IC code
define DesiredTemp 21[/code]
Default DesiredTemp is set to 21 degrees Celsius
[h1]Important[/h1]
You must place the daylight sensor in the correct position, like here https://steamcommunity.com/sharedfiles/filedetails/?id=1698441282
The large extendable radiator must be positioned strictly as shown.
The performance depends on the planet, the environment and the strength of the sun's radiation.
If the atmosphere contains volatiles, manually pump them out of the radiator chamber. Otherwise, autoignition may occur.
[h1]Extending[/h1]
If performance is not enough for you, just add additional elements.
Do not forget to isolate the radiators from the external environment.
[h1]Note[/h1]
For temperature correction, a bi-directional load-compensated hysteresis is used.
This heat transfer control feature automatically controls the temperature supplied to your radiators. When the room is cold, the temperature supplied to the radiators will be high, but as the room warms up, less heat is needed and the temperature supplied to the radiators will decrease. This means that the room will reach the desired temperature in a shorter time than a simple on/off control. It also allows you to compensate for the load, if the temperature in the room rises or falls sharply, the heat pump begins to transfer heat more intensively, so the temperature will not go beyond the limits.
[h1]Game version support[/h1]
0.2.3920.18842 06/04/2023[F&S] Industrial Heat Pump on Nxeon
From our catalogue- One-click install
- Not available. One-click install isn't available for this game's mods yet. Download it and upload it to your server in Files.
- Server load
- light
- Smallest plan we suggest
- Stationeers — 4 GB (4 GB RAM). This follows our own load rating above, not a benchmark.
Run [F&S] Industrial Heat Pump on a Stationeers server
Deploy a server above, then upload the file in Files.
What kind of mod it is
From the catalogTechnology & automation
Machines, power, logistics and automation.
Compatibility
- Game
- Stationeers
- File size
- 24 KB
Verified at the source
- ✓Steam WorkshopOfficial listing, checked 2026-09-24Open ↗
- ✓Author123, as published on Steam Workshop
- ✓LicenseNot published by the sourceFree