Source-checkedTechnology & automation

[F&S] Logic Reader\Writer\Batch

by 123 · for Stationeers

Description Does the same as the logic circuits reader/writer/batch, replaces 6 devices.​ Requirements 1 IC Housing. 1 Integrated Circuit (IC10). IC ports description Port Device D0 Logic Reader 1…

281Downloads
49 KBFile size
Steam WorkshopSource

About [F&S] Logic Reader\Writer\Batch

From Steam Workshop

Description Does the same as the logic circuits reader/writer/batch, replaces 6 devices.​ Requirements 1 IC Housing. 1 Integrated Circuit (IC10). IC ports description Port Device D0 Logic Reader 1…

Description

Does the same as the logic circuits reader/writer/batch, replaces 6 devices.​

Requirements

[olist] [*]1 IC Housing. [*]1 Integrated Circuit (IC10). [/olist]

IC ports description

[table] [tr] [th]Port[/th] [th]Device[/th] [/tr] [tr] [td]D0[/td] [td]Logic Reader 1 (Optional)[/td] [/tr] [tr] [td]D1[/td] [td]Logic Reader 2 (Optional)[/td] [/tr] [tr] [td]D2[/td] [td]Logic Reader 3 (Optional)[/td] [/tr] [tr] [td]D3[/td] [td]Logic Writer 1 from Reader 1 (Optional)[/td] [/tr] [tr] [td]D4[/td] [td]Logic Writer 2 from Reader 2 (Optional)[/td] [/tr] [tr] [td]D5[/td] [td]Logic Writer 3 from Reader 3 (Optional)[/td] [/tr] [/table]

Changeable values in IC code

##### Reader D0 to D3 Writer #####
# Reader Deice Logic Type
push LogicType.Setting
# Writer Deice Logic Type
push LogicType.On
push 0 # Enable batch mode for reader 1=yes,0=no
push 3 # 0=Average,1=Sum,2=Minimum,3=Maximum
push 0 # Enable batch mode for writer 1=yes,0=no
##### Reader D1 to D4 Writer #####
# Reader Deice Logic Type
push LogicType.Setting
# Writer Deice Logic Type
push LogicType.On
push 0 # Enable batch mode for reader 1=yes,0=no
push 3 # 0=Average,1=Sum,2=Minimum,3=Maximum
push 0 # Enable batch mode for writer 1=yes,0=no
##### Reader D2 to D5 Writer #####
# Reader Deice Logic Type
push LogicType.Setting
# Writer Deice Logic Type
push LogicType.On
push 0 # Enable batch mode for reader 1=yes,0=no
push 3 # 0=Average,1=Sum,2=Minimum,3=Maximum
push 0 # Enable batch mode for writer 1=yes,0=no
################################################

Configuring settings

Open code in editor, and set values. (Change only the values highlighted in red)

About LogicType.*

You can get other device values with tablet and device configuration cartridge

Game version support

0.2.3920.18842 06/04/2023

[F&S] Logic Reader\Writer\Batch on Nxeon

From our catalogue
One-click install
Not available. One-click install isn't available for this game's mods yet. Download it and upload it to your server in Files.
Server load
light
Smallest plan we suggest
Stationeers — 4 GB (4 GB RAM). This follows our own load rating above, not a benchmark.

Run [F&S] Logic Reader\Writer\Batch on a Stationeers server

Deploy a server above, then upload the file in Files.

What kind of mod it is

From the catalog
Listed on Steam Workshop as “Workshop”

Technology & automation

Machines, power, logistics and automation.

Compatibility

Game
Stationeers
File size
49 KB

Verified at the source

  • ✓Steam WorkshopOfficial listing, checked 2026-09-24Open ↗
  • ✓Author123, as published on Steam Workshop
  • ✓LicenseNot published by the sourceFree

[F&S] Logic Reader\Writer\Batch, answered

Generated from the mod’s own source data.

Is it free?

Yes. [F&S] Logic Reader\Writer\Batch is free to download from Steam Workshop.

How do I add it to my Nxeon server?

One-click install isn't available for this game's mods yet. Download [F&S] Logic Reader\Writer\Batch from Steam Workshop and upload it to your Nxeon Stationeers server in Files.

NxLabs

Run [F&S] Logic Reader\Writer\Batch on a Stationeers server.

Deploy in about a minute from $8.99 a month, then upload [F&S] Logic Reader\Writer\Batch in Files.