Source-checkedTechnology & automation

[F&S] MinMax Switch

by 123 · for Stationeers

Description Turns on the specified device at the minimum value and turns it off when the maximum value is reached. Requirements 1 IC Housing. 1 Integrated Circuit (IC10). 1 Any device that needs to…

653Downloads
4 yr agoLast updated
23 KBFile size
Steam WorkshopSource

About [F&S] MinMax Switch

From Steam Workshop

Description Turns on the specified device at the minimum value and turns it off when the maximum value is reached. Requirements 1 IC Housing. 1 Integrated Circuit (IC10). 1 Any device that needs to…

Description

Turns on the specified device at the minimum value and turns it off when the maximum value is reached.

Requirements

[olist] [*]1 IC Housing. [*]1 Integrated Circuit (IC10). [*]1 Any device that needs to be turned on / off depending on the data [*]1 Any analyzer or device from which data is read [/olist]

IC ports description

[table] [tr] [th]Port[/th] [th]Device[/th] [/tr] [tr] [td]D0 (Device)[/td] [td]Any device that needs to be turned on / off depending on the data[/td] [/tr] [tr] [td]D1 (Analyzer)[/td] [td]Any analyzer or device from which data is read[/td] [/tr] [/table]

Chip states

[table] [tr] [th]State[/th] [th]Description[/th] [/tr] [tr] [td]0[/td] [td]All fine[/td] [/tr] [tr] [td]1[/td] [td]D0 - not connected[/td] [/tr] [tr] [td]2[/td] [td]D1 - not connected[/td] [/tr] [/table]

Configuring settings

Open code in editor, and set values. (Change only the values highlighted in red)

About LogicType.*

You can get other device values with tablet and device configuration cartridge

Notes

now for 1 game tick, the pressure can increase significantly, and then distributed through the pipe, remember, otherwise the switch may not work properly.

Related

[F&S] Max/Min Switch https://steamcommunity.com/sharedfiles/filedetails/?id=2812548305

Game version support

0.2.3920.18842 06/04/2023

Highlights

From source data

Footprint

A 23 KB download, rated a light load on a server.

Last update

Its author last shipped an update 4 yr ago.

[F&S] MinMax Switch on Nxeon

From our catalogue
One-click install
Not available. One-click install isn't available for this game's mods yet. Download it and upload it to your server in Files.
Server load
light
Smallest plan we suggest
Stationeers — 4 GB (4 GB RAM). This follows our own load rating above, not a benchmark.
Latest build
2022-05-25, released 2022-05-25, 23 KB

Game versions by loader

LoaderGame versionsNewest
Workshop

From 1 recorded build of [F&S] MinMax Switch.

Run [F&S] MinMax Switch on a Stationeers server

Deploy a server above, then upload the file in Files.

What kind of mod it is

From the catalog
Listed on Steam Workshop as “Workshop”

Technology & automation

Machines, power, logistics and automation.

Compatibility

Game
Stationeers
File size
23 KB

Verified at the source

  • ✓Steam WorkshopOfficial listing, checked 2026-10-10Open ↗
  • ✓Author123, as published on Steam Workshop
  • ✓LicenseNot published by the sourceFree

[F&S] MinMax Switch, answered

Generated from the mod’s own source data.

Is it free?

Yes. [F&S] MinMax Switch is free to download from Steam Workshop.

How do I add it to my Nxeon server?

One-click install isn't available for this game's mods yet. Download [F&S] MinMax Switch from Steam Workshop and upload it to your Nxeon Stationeers server in Files.

NxLabs

Run [F&S] MinMax Switch on a Stationeers server.

Deploy in about a minute from $8.99 a month, then upload [F&S] MinMax Switch in Files.