About [F&S] Room Temperature Control
From Steam WorkshopDescription Allows you to control the temperature in the room within the specified limits. This scheme works fine in small rooms and use hysteresis method to prevent unwanted rapid switching.…
Description
Allows you to control the temperature in the room within the specified limits. This scheme works fine in small rooms and use hysteresis method to prevent unwanted rapid switching.
Requirements
[olist] [*]1 IC Housing. [*]1 Integrated Circuit (IC10). [*]1 Gas Sensor. [*]1 Dial. (Optional not required) The dial works in the range of 0C - 45C [*]At least one Cooler. (Connected pipes must be under pressure (CO2 are best choise) and have radiators in the external environment) (Support Gas/Liquid coolers) [*]At least one Heater. [/olist]
IC ports description
[table] [tr] [th]Port[/th] [th]Device[/th] [/tr] [tr] [td]D0[/td] [td]Gas Sensor[/td] [/tr] [tr] [td]D1[/td] [td]Dial. (Optional not required. If not mounted then the standard temperature will be 21C)[/td] [/tr] [tr] [td]D2[/td] [td]Alert. (Optional not required. Turns on the specified device. You can use any device that supports On/Off) [/td] [/tr] [/table]
Changeable values in IC code
define DesiredTemp 21 # temp in celsius
define HysteresisWindow 2 # temp difference +-2
define CheckVolatiles 1 # 1=yes,0=no
define VolatilesRatio 0.0003 # 0.03% on tablet
Chip states
[table] [tr] [th]State[/th] [th]Description[/th] [/tr] [tr] [td]0[/td] [td]All fine[/td] [/tr] [tr] [td]1[/td] [td]Low pressure (If pressure less 7 kPa IC Chip will not turn on temperature control and will sends a signal to port D2)[/td] [/tr] [tr] [td]2[/td] [td]Detected more then 0.03% of volatiles in atmosphere, automatically shuts off heaters (coolers will still work) and sends a signal to port D2.[/td] [/tr] [tr] [td]3[/td] [td]Temperature too high (if the temperature is set to 21, and the gas sensor shows 31, sends a signal to port D2)[/td] [/tr] [tr] [td]4[/td] [td]Temperature too low (if the temperature is set to 21, and the gas sensor shows 11, sends a signal to port D2)[/td] [/tr] [/table]
Important
It is strongly recommended not to disable or change the volatiles checker. Insulated pipes must be laid in the room so as not to receive heat leakage. For best results don't place gas sensor near cooler/heater.
Game version support
0.2.3920.18842 06/04/2023
Highlights
From source dataFootprint
A 18 KB download, rated a light load on a server.
Last update
Its author last shipped an update 4 yr ago.
[F&S] Room Temperature Control on Nxeon
From our catalogue- One-click install
- Not available. One-click install isn't available for this game's mods yet. Download it and upload it to your server in Files.
- Server load
- light
- Smallest plan we suggest
- Stationeers — 4 GB (4 GB RAM). This follows our own load rating above, not a benchmark.
- Latest build
- 2023-04-15, released 2023-04-15, 18 KB
Game versions by loader
| Loader | Game versions | Newest |
|---|---|---|
| Workshop |
From 1 recorded build of [F&S] Room Temperature Control.
Run [F&S] Room Temperature Control on a Stationeers server
Deploy a server above, then upload the file in Files.
What kind of mod it is
From the catalogWorkshop
Its source category doesn’t say more about what it does, so NxLabs lists it under Other.
Compatibility
- Game
- Stationeers
- File size
- 18 KB
Verified at the source
- ✓Steam WorkshopOfficial listing, checked 2026-10-10Open ↗
- ✓Author123, as published on Steam Workshop
- ✓LicenseNot published by the sourceFree