Source-checkedOther

Temperature Management

by Sunset · for Stationeers

# Temperature Management Source available on GitHub: https://github.com/RoboPhred/stationeers-mips/tree/master/temperature-management ## Description Monitors the temperature of a gas sensor and…

93Downloads
160 KBFile size
Steam WorkshopSource

About Temperature Management

From Steam Workshop

# Temperature Management Source available on GitHub: https://github.com/RoboPhred/stationeers-mips/tree/master/temperature-management ## Description Monitors the temperature of a gas sensor and…

# Temperature Management

Source available on GitHub: https://github.com/RoboPhred/stationeers-mips/tree/master/temperature-management

## Description

Monitors the temperature of a gas sensor and mantains temperature through the use of coolers and heaters.

## Features

- Shmitt triggered - Supports batch writers and direct wall heaters / wall coolers - Optional external temperature control - Status reports via Status output.

## Devices

1. GasSensor Type: _Gas Sensor_ The gas sensor to measure the temperature from 2. Heater Type: _Memory_ or _Wall Heater_ The device to turn on when the room needs to be heated. For batch writer use, attach a memory cell, and attach the cell to a batch writer. 3. Cooler Type: _Memory_ or _Wall Heater_ The device to turn on when the room needs to be cooled. For batch writer use, attach a memory cell, and attach the cell to a batch writer. 4. DesiredTemperatureDevice _optional_ Type: _Memory_ or _Dial_ The external source to specify the temperature. By default, this is Celcius, but can be Kelvin by a config option.

## Configuration

- `DesiredTemperature` Default: _295.15 Kelvin, 22 Celcius_ The target temperature to mantain in Kelvin. - `Threshold` Default: _1 Kelvin / Celcius_ The offset in degrees Kelvin to allow the temperature to differ from DesiredTemperature before trying to correct it. - `ExternalDesiredTempUnits` Default: _1_ (Celcius mode) The units to expect the value from DesiredTemperatureDevice in. If 1, use Celcius, if 0, use Kelvin. - `CheckInterval` Default: _1_ The time in seconds to wait between temperature checks.

## Status codes

- `-1`: Cooling - `0`: Idle - `1`: Heating

Temperature Management on Nxeon

From our catalogue
One-click install
Not available. One-click install isn't available for this game's mods yet. Download it and upload it to your server in Files.
Server load
light
Smallest plan we suggest
Stationeers — 4 GB (4 GB RAM). This follows our own load rating above, not a benchmark.

Run Temperature Management on a Stationeers server

Deploy a server above, then upload the file in Files.

What kind of mod it is

From the catalog
Listed on Steam Workshop as “Workshop”

Workshop

Its source category doesn’t say more about what it does, so NxLabs lists it under Other.

Compatibility

Game
Stationeers
File size
160 KB

Verified at the source

  • ✓Steam WorkshopOfficial listing, checked 2026-09-24Open ↗
  • ✓AuthorSunset, as published on Steam Workshop
  • ✓LicenseNot published by the sourceFree

Temperature Management, answered

Generated from the mod’s own source data.

Is it free?

Yes. Temperature Management is free to download from Steam Workshop.

How do I add it to my Nxeon server?

One-click install isn't available for this game's mods yet. Download Temperature Management from Steam Workshop and upload it to your Nxeon Stationeers server in Files.

NxLabs

Run Temperature Management on a Stationeers server.

Deploy in about a minute from $8.99 a month, then upload Temperature Management in Files.